This AAC autoclave battery system is the core curing section of an aerated concrete production line. It consists of multiple horizontal autoclaves, ferry carts, autoclave trolleys, a steam piping network, a PLC control cabinet and a heat recovery module.
After cutting, AAC green cakes are grouped on trolleys and sent into the autoclave battery. Under saturated steam of 1.0–1.3 MPa and 180–195°C, a hydrothermal reaction takes place to form stable calcium silicate hydrate, giving AAC blocks and panels the required compressive strength and dimensional stability. The battery layout is designed to match plant capacity, from 50,000 m³/year up to 300,000 m³/year and above.
Cut green cakes are loaded onto autoclave trolleys and transported by ferry cart into idle autoclaves within the battery. The system runs a standard curing sequence:
While one autoclave is in the holding stage, another can finish discharging and accept new trolleys. This staggered cyclic mode eliminates long waiting times. Recovered flash steam is reused for preheating boiler feed water or the pre-curing chamber, forming closed-loop thermal management. Finished AAC products are then conveyed out for separation, stacking and packaging.

We provide complete engineering service for the autoclave battery system: layout design matched to your workshop, fabrication, pressure vessel inspection, site installation, commissioning, operator training and after-sales maintenance.
We also optimize steam balance and cycle timing according to your raw material formula (sand or fly ash) and target product, to maximize plant yield and reduce cracking rate. CE and ISO compliant documentation is available for overseas projects.

A 150,000 m³/year AAC plant in the Middle East adopted our 8-unit AAC autoclave battery system. The original single-autoclave setup caused frequent production pauses and unstable block strength. After retrofitting to a grouped battery configuration with automatic ferry and heat recovery, the plant achieved the following results:
The customer now runs a stable supply for local residential and infrastructure projects and plans to expand the battery set in phase two.